Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1) – Anbesec

Short Description:


Product Detail

Related Video

Feedback (2)

Our focus on should be to consolidate and enhance the quality and repair of present products, in the meantime constantly establish new products to meet unique customers' requires for Linear Heat Detector For Hazardous Locations, Resettable Linear Heat Detector, Water Pump For Misting System, We have been searching ahead to even better cooperation with overseas buyers dependant on mutual benefits. Be sure to really feel totally free to speak to us for additional element!
Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

We will constantly satisfy our respected customers with our good excellent, superior value and superior assistance due to we're additional experienced and far more hard-working and do it in cost-effective way for Factory wholesale Water Mist System Testing - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Guyana, Bangladesh, Estonia, We only supply quality items and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom merchandise etc that can according to customer's requirement.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Nora from Barbados - 2018.02.04 14:13
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Teresa from Indonesia - 2017.03.07 13:42

    Send your message to us: