OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec

Short Description:


Product Detail

Related Video

Feedback (2)

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as theory of "quality the basic, have faith in the initial and administration the advanced" for Water Mist Fire Protection, Water Mist Spray System Cost, Linear Heat Sensor Cable, If needed, welcome to help make speak to with us by our web page or cellular phone consultation, we are going to be delighted to serve you.
OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

We believe that long term partnership is a result of high quality, value added service, rich experience and personal contact for OEM Customized Mist Sprinkler - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: New York, Guatemala, Kyrgyzstan, We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on "Integrity, Profession, Win-win Cooperation", because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Emma from Detroit - 2018.02.08 16:45
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Karl from Washington - 2017.03.07 13:42

    Send your message to us: