We have been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for Fire Alarm Beam Detector, Fire Water Mist System, Fike Linear Heat Detecor, We will supply high-quality solutions and fantastic companies at aggressive charges. Start benefiting from our comprehensive providers by contacting us today.
One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1) – Anbesec Detail:

High-pressure plunger pump

1

High pressure plunger pump  is one of the core components of high pressure water mist system, our company high-pressure plunger pump adopts foreign advanced technology, it has the advantages of long service life and stable performance. Liquid end is made of brass production.

 

High-pressure plunger pump main technical parameters:

specifications

Flow rate(L/min)

Working pressure(Mpa)

power(KW)

Rotating speed

(r/min)

origin

HAWK-HFR80FR

80

28

42

1450

Italy

Pressure-stabilizing pump

2

The pressure stabilizing pump is to stabilize the pressure in the pipeline. After the zone valve is opened, the pipeline pressure is under The pressure stabilizing pump will start automatically. After running for more than 10 seconds, the pressure still cannot reach 16bar, automatically start the high-pressure main pump. The stabilizer pump is made of stainless steel.

 

 

Pump motor

水泵电机

Our company’s high-pressure water mist automatic fire extinguishing system adopts frequency conversion, speed-adjustable, three-phase asynchronous motor.

When selecting  high pressure water mist fire extinguishing system, the rated speed of the motor should meet the speed requirements of the pump, selection of the power of the motor should be based on the working pressure and the flow rate of the water pump.

N=2PQ*10-2

N—-Motor power(Kw);

O—–Working pressure of water pump(MPa);

P—-Flow of water pump(L/min)

High pressure water mist nozzle

4

 

The high-pressure water mist nozzle consists of the main body of the nozzle, the swirl core of the nozzle, and the nozzle main body, filter screen, filter screen sleeve, etc. Under certain water pressure, the water is atomized by centrifugation, impact, jet and other methods.

 

Community-verified icon

 

Technical parameters:

Specification model Rated flow rate(L/min) Minimum working pressure (MPa) Maximum installation distance (m) Height of installation (m)
XSWT0.5/10 5 10 3 According to the design specification
XSWT0.7/10 7 10 3
XSWT1.0/10 10 10 3
XSWT1.2/10 12 10 3
XSWT1.5/10 15 10 3

Pressure regulating relief valve

5

 

The pressure regulating relief valve is connected with the high-pressure water pump and the water tank, when the main pump pressure is too high, the discharged water can flow back to the storage tank. The pressure regulating relief valve is made of brass.

 

Safety relief valve

6

The pressure value of relief action of the safety relief valve is 16.8MPa, and the safety relief valve also known as safety overflow valve is an automatic pressure relief device driven by medium pressure. The safety relief valve is made of stainless steel.

 

Water storage tank

7

 

Stainless steel water storage tank ensure automatic water replenishment, and is equipped with a liquid level display device, low liquid level alarm device and overflow and  venting  device.

 


Product detail pictures:

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures

One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1)  – Anbesec detail pictures


Related Product Guide:

With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for One of Hottest for Water Mist Fire System Test - High pressure water mist fire extinguishing system(2.1) – Anbesec , The product will supply to all over the world, such as: Puerto Rico, Rotterdam, Tunisia, High output volume, top quality, timely delivery and your satisfaction are guaranteed. We welcome all inquiries and comments. If you are interested in any of our products or have an OEM order to fulfill, please feel free to contact us now. Working with us will save you money and time.
  • The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Delia Pesina from Mauritius - 2018.09.29 13:24
    Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Kimberley from Rwanda - 2017.04.28 15:45

    Send your message to us: